Register Name / Module Address | Assembled Address for PLC | Description |
---|---|---|
Set Left Motor Port Digital Control 4:0060 |
M: 4:1801 E: O.Data [1] P: Byte 2 (Hi) Byte 3 (Lo) |
Bitwise value – “1” Energizes Output: bit 0 = Motor Port Pin 3 bit 1 = Motor Port Pin 4 bit 2 = Motor Port Pin 5 bit 3 thru bit 7 = Reserved bit 8 = Clear over-current error bit 9 thru 14 = Reserved bit 15 = Digital Output Enable 0 = Use Port as Motor Control 1 = Use Port as Digital Outputs |
Set Right Motor Port Digital Control 4:0048 |
M: 4:1802 E: O.Data [2] P: Byte 4 (Hi) Byte 5 (Lo) |
|
Reserved | M: 4:1803 E: O.Data [3] P: Byte 6 (Hi) Byte 7 (Lo) |