Many Hippotizer system have the ability to use an external Genlock signal in order to ensure the vertical refresh occurs in sync across multiple systems.

Note: Genlock synchronises the vertical refresh only; synchronising frame playback is handled by timecode.

Genlock can be taken from an external source, refered to as house sync, or sourced from a display output. Where multiple systems are being used an external sync source must be used.

House Sync

The Genlock input on Hippotizer is compatible with sync signals including:

  • Black Burst
  • Tri-Level
  • SD/HD/3G SDI signals.

Only displays that have identical resolutions and EDIDs can be synced together. It is strongly advised to emulate the same EDID on displays that are to be Genlocked. Information on EDID emulation can be found here.