**If more parameters are required, the number of channels can be changed by adding a text file to the Notch Block folder:

  • Shut down the Engine and Zookeeper
  • On the Hippotizer, navigate to Documents/Green Hippo/Notch
  • Create a text document and name it Params.txt
  • Open the text document and add two lines:
numtextparams=5
numfaderparams=20
firstparamiszero=true 
  • Save the text file and close it
  • Restart the engine

The variables to consider when editing the number of parameters of Notch:

Text Parameters

  • 2 by default
  • No Limit to how many can be created

Fader Parameters (Floats)

  • 10 by default
  • No limit to how many can be created

First Parameter is Zero

Notch’s DMX offset table adds an offset to each DMX address. If first parameter is zero is set to true, any offset will be overridden forcing DMX to start from 1.