Register Name / Module Address | Assembled Address for PLC | Description |
---|---|---|
Sensor & Control Port Inputs 4:0035 |
M: 4:1518 E: I.Data [18] P: Byte 36 (Hi) Byte 37 (Lo) |
Bitwise Value – Read Only: bit 0 = Left Sensor Port – Pin 3 bit 1 = Left Control Port – Pin 3 bit 2 = Right Sensor Port – Pin 3 bit 3 = Right Control Port – Pin 3 bit 4 = Left Sensor Port – Pin 4 bit 5 = Left Control Port – Pin 4 bit 6 = Right Sensor Port – Pin 4 bit 7 = Right Control Port – Pin 4 bit 8 – 14 Reserved bit 15 = 2 sec on / 2 sec off heatbeat |
Reserved | M: 4:1519 E: I.Data [19] P: Byte 38 (Hi) Byte 39 (Lo) |
Used for Reset Protection connection See topic Assemblies with Reset Protection for details |
ConveyStop Status 4:0019 |
M: 4:1520 E: I.Data [20] P: Byte 40 (Hi) Byte 41 (Lo) |
Bitwise Value – Read Only: bit 0 – 4 Reserved bit 5 = Stop active on another module in Stop Group bit 6 = Stop active due to lost communication connection bit 7 = Stop active due to lost PLC connection bit 8 = Stop active on local module’s Left Control Port bit 9 = Stop active on local module’s Right Control Port bit 10 = Stop active due to Stop Command from PLC bit 11 – 15 Reserved |