Module Address |
Register Name |
Ethernet I/P Tag |
Modbus PLC Holding Register |
4:0020 |
ConveyStop Command |
E: O.Data [0] |
M: 4:3800 |
4:0060 |
Set Left Motor Port Digital Control |
E: O.Data [1] |
M: 4:3801 |
4:0084 |
Set Right Motor Port Digital Control |
E: O.Data [2] |
M: 4:3802 |
4:0037 |
Control Port Digital Output Control |
E: O.Data [3] |
M: 4:3803 |
4:0260 |
Left Motor Run / Reverse |
E: O.Data [4] |
M: 4:3804 |
4:0261 |
Left Motor Brake Method |
E: O.Data [5] |
M: 4:3805 |
4:0262 |
Left Motor Speed Control Method |
E: O.Data [6] |
M: 4:3806 |
4:0270 |
Right Motor Run / Reverse |
E: O.Data [7] |
M: 4:3807 |
4:0271 |
Right Motor Brake Method |
E: O.Data [8] |
M: 4:3808 |
4:0272 |
Right Motor Speed Control Method |
E: O.Data [9] |
M: 4:3809 |
4:0040 |
Left Motor Speed Reference |
E: O.Data [10] |
M: 4:3810 |
4:0064 |
Right Motor Speed Reference |
E: O.Data [11] |
M: 4:3811 |
4:0043 |
Left Motor Acceleration Ramp |
E: O.Data [12] |
M: 4:3812 |
4:0044 |
Left Motor Deceleration Ramp |
E: O.Data [13] |
M: 4:3813 |
4:0067 |
Right Motor Acceleration Ramp |
E: O.Data [14] |
M: 4:3814 |
4:0068 |
Right Motor Deceleration Ramp |
E: O.Data [15] |
M: 4:3815 |
4:0022 |
Clear Motor Error |
E: O.Data [16] |
M: 4:3816 |
4:0196 |
Set Status to Downstream Module |
E: O.Data [17] |
M: 4:3817 |
4:0116 |
Set Status to Upstream Module |
E: O.Data [18] |
M: 4:3818 |
4:0034 |
Sensor Port Input Signal Condition Mask |
E: O.Data [19] |
M: 4:3819 |
4:0201 |
Set Discharge Tracking Word 1 |
E: O.Data [20] |
M: 4:3820 |
4:0202 |
Set Discharge Tracking Word 2 |
E: O.Data [21] |
M: 4:3821 |
N/A |
Set Module Reset Count |
E: O.Data [22] |
M: 4:3822 |
4:0008 |
Left Motor Servo Command Pulses |
E: O.Data [23] |
M: 4:3823 |
4:0009 |
Left Motor Servo Command Word |
E: O.Data [24] |
M: 4:3824 |
4:0013 |
Right Motor Servo Command Pulses |
E: O.Data [25] |
M: 4:3825 |
4:0014 |
Right Motor Servo Command Word |
E: O.Data [26] |
M: 4:3826 |