The cable and connectors of GeoNave display have labels that easily identify the proper connections that must be made. Couple connectors identified with the same inscriptions for correct installation.

Installing the display and GNSS antenna

The following image illustrates the required connections to instal the GeoNave display and GNSS antenna on the tractor.

Item Description
GeoNave display
GNSS antenna cable
GNSS antenna
Display power cable
Battery connection cable with fuse holder
12 V battery

Connecting the display to the sprayer cable

GeoNave display connection to the sprayer cable must follow the schematic shown below.

Item Description
GeoNave display
Sprayer cabin cable
Sprayer cable extender
Sprayer implement cable

Connecting the sprayer implement cable to the implement

There are several sprayer implement configurations according to valve model, number of sections, presence of regulating valve, main valve, flowmeter and other sensors. For each configuration it is possible to have a different cable kit, using the items described on System Components.

Following are some examples of GeoNave system configurations for spraying.

Example 1: Crop Sprayer, 2-wire valves, DIN 43650-B connectors

  • 9 x Section valve 2-wire DIN 43650-B
  • Main control valve 2-wire DIN 43650-B
  • Regulation valve 2-wire DIN 43650-B
  • Flowmeter 3-wire Amp Superseal
  • Pressure transducer 3-wire Amp Superseal

Item Description
Sprayer implement cable
  • C00902226 – 9 x Section valve
  • C00902228 – 5 x Section valve
9 x Section valve 2-wire DIN 43650-B connector
Regulation valve 2-wire DIN 43650-B connector
Main control valve 2-wire DIN 43650-B connector
Flowmeter 3-wire Amp Superseal connector
Pressure transducer 3-wire Amp Superseal connector

Example 2: Crop Sprayer, 3-wire valves, DIN 43650-B connectors

  • 9 x Section valve 3-wire DIN 43650-B
  • Main control valve 3-wire DIN 43650-B
  • Regulation valve 2-wire DIN 43650-B
  • Flowmeter 3-wire Amp Superseal
  • Pressure transducer 3-wire Amp Superseal

Item Description
Sprayer implement cable
  • C00902227 – 9 x Section valve
  • C00902238 – 5 x Section valve
Power cable for 3-wire valves
12 V battery
9 x Section valve 3-wire DIN 43650-B connector
Regulation valve 2-wire DIN 43650-B connector
Main control valve 3-wire DIN 43650-B connector
Flowmeter 3-wire Amp Superseal connector
Pressure transducer 3-wire Amp Superseal connector

Example 3: Orchard sprayer, solenoid valves and optional ultrasonic sensors

  • up to 6 x Section valves with solenoid DIN 43650
  • 2 x Orchard ultrasonic sensors 5-wire M12 (optional)

Item Description
Sprayer implement cable – C00902230
up to 6 x Section valve with solenoid DIN 43650 connector
2 x Orchard ultrasonic sensor adapter 5-wire M12 connector
2 x Orchard ultrasonic sensor 5-wire M12 connector

Example 4: Multirow sprayer, up to 6 sections 3-wire valves with DIN 43650-B connectors and optional ultrasonic sensors

  • up to 6 x Section valve 3-wire DIN 43650-B
  • Main control valve 3-wire DIN 43650-B
  • Regulation valve 2-wire DIN 43650-B
  • Flowmeter 3-wire Amp Superseal
  • Pressure transducer 3-wire Amp Superseal
  • 2 x Orchard ultrasonic sensor 5-wire M12 (optional)

Item Description
Sprayer implement cable – C00902231
Power cable for 3-wire valves
12 V battery
6 x Section valve 3-wire DIN 43650-B connector
Regulation valve 2-wire DIN 43650-B connector
Main control valve 3-wire DIN 43650-B connector
Flowmeter 3-wire Amp Superseal connector
Pressure transducer 3-wire Amp Superseal connector
2 x Orchard ultrasonic sensor adapter 5-wire M12 connector
2 x Orchard ultrasonic sensor 5-wire M12 connector