EasyRoll Software / Advanced Dialog / Pin 2 Usage Tab /
Most Upstream Zone
By default and without any intervention, the most upstream zone will never turn on to accept new product. To cause the most upstream zone to run to accept an item with a wired signal, you need to utilize the Aux I/O Pin 2 for the upstream zone as a Wake-up input.
Assuming the most upstream zone is connected to the left side of the module; we set the Left Pin 2 to Wake up from the drop-down box and make sure we click the UP arrow to indicate that the Left Pin 2 signal is to be associated with the Upstream Zone. When the Left Pin 2 signal is energized, the upstream zone will run to accept an item |