In this area the user obtains information to make a self-diagnosis of possible problems with the system IsoView ISO 30.
Problem |
Possible solutions |
The monitor does not turn on. |
- Check the correct connection of the cable to the tractor battery.
- Check the integrity of the fuse present in the battery cable.
- Check the correct and secure connection of the power cable to the battery cable.
- Check the correct and secure connection of the power cable to the monitor.
- Check if any of the cables are broken.
|
Touch screen unresponsive. |
|
Signal GNSS weak or absent. |
- Make sure the antenna GNSS is facing the open sky. Obstruction sites can deteriorate the signal GNSS.
- Check the correct installation of the antenna GNSS on the roof of the tractor.
- Check antenna cable integrity GNSS, if there are no breaks or folds.
- With the aid of a multimeter, check the voltage of 5 V present in the antenna cable GNSS.
- if the antenna GNSS is close to dense forest areas, disable the Signal Filter GPS. Note: Positioning accuracy is degraded by forest obstructions.
|
Portable memory is not recognized. |
- Ensure the portable memory size is not more than 8GB.
- Format the memory as FAT32 and default allocation size as described in the Firmware Update.
|
Unable to configure Spray valves and sensors |
- Get in touch with the commercial area to acquire the spraying kit and license according to your machine.
|
Unable to access Fertilization menu |
- Get in touch with the commercial area to acquire the Fertilization kit and license according to your machine.
|
Unable to access Pilot menu |
- Get in touch with the commercial area to acquire the Autopilot kit and license according to your machine.
|
If any of the problems listed above persist, contact the team Support and Technical Assistance for the correct diagnosis.