After visual check and the necessary adjustments, if necessary, we will check the condition of your battery before connecting the System.

Using a multimeter, perform the following procedure:

Item Description Procedure Recommendation Action
1 With the machine turned off Check battery voltage From 12V to 13V Check electrical system/replace battery
2 During engine start Approximately 12V
3 With all accessories and implements turn on the engine and lighting Approximately 14V

connecting to battery

Item Description
1 Make sure the machinery is turned off using the main switch or that you have the ignition key on.
2 Connect the M8 eye terminal of the Red cable where the Fuse Holder is to the Positive Pole “+” from 12V battery.
3 Connect the M8 eyelet of the Black cable to the Negative Pole “-” from 12V battery
4 Check the tightness of the screws and take up any slack.
6 Turn on the main switch or use the ignition key to power the System IsoView.
7 Now let’s go to Chapter Diagnosis operating system to check some information about your system IsoView.