Connecting to Rockwell PLCs with Ethernet I/P / Using AddOn Instructions / AOI Tag Descriptions / ConveyLinx-ERSC Family /


ZPA Mode Outputs

ConveyLinx ERSC ConveyLinx-Ai 24V ConveyLinx-Ai 48V
ConveyLinx-ECO ZPA Mode PLC I/O Mode

Tag Name Data Type Module Register Bit Description
O_Acc_Arr_DNZn BOOL 4:0184 0 Set Local Downstream Zone to Accumulate
O_Acc_Arr_UPZn BOOL 4:0104 0 Set Local Upstream Zone to Accumulate
O_Acc_Adj Upstr_To_DNZn BOOL 4:0184 8 Accumulate Adjacent Upstream to Local Downstream Zone
O_Acc_Adj_Upstr_To_UPZn BOOL 4:0104 8 Accumulate Adjacent Upstream to Local Upstream Zone
O_Clear_Jam_DNZn BOOL 4:0189 0 Clear Jam at Local Upstream Zone
O_Clear_Jam_UPZn BOOL 4:0109 0 Clear Jam at Local Downstream Zone
O_Clear_Motor_Error BOOL 4:0022 0 Clear Motor Error Left & Right
O_ConfArrival_ToDNZn BOOL 4:0184 9 Confirm Downstream Arrival for Local Downstream Zone
O_ConfArrival_ToUPZn BOOL 4:0104 9 Confirm Downstream Arrival for Local Upstream Zone
O_ConveyMerge_Enable_PLC_Ctrl BOOL 4:0387 15 Set to enable PLC over-ride of configured ConveyMerge
O_ConveyMerge_Disable_Center BOOL 4:0387 4 Set to disable center release
O_ConveyMerge_Disable_Left BOOL 4:0387 5 Set to disable left release
O_ConveyMerge_Disable_Right BOOL 4:0387 6 Set to disable right release
O_ConveyMerge_Priority SINT 4:0387 - Numerical value to set merge priority
O_Control_Port_Output_Left BOOL 4:0063 1 Set Left Control Port Output
O_Control_Port_Output_Right BOOL 4:0063 3 Set Right COntrol Port Output
O_ConveyStop_Command INT 4:0020 - Set Local ConveyStop Command Word
O_DA_Mode_Cmd_DNZn SINT 4:0375 Lo Byte Direction & Accumulation Mode Command Byte for Downstream Zone
O_DA_Mode_Cmd_UPZn SINT 4:0365 Lo Byte Direction & Accumulation Mode Command Byte for Upstream Zone
O_DA_Mode_Value_DNZn SINT 4:0375 Hi Byte Direction & Accumulation Mode Data Byte for Downstream Zone
O_DA_Mode_Value_UPZn SINT 4:0365 Hi Byte Direction & Accumulation Mode Data Byte for Upstream Zone
O_Enable_Module BOOL - AOI Logic Enable Output to ERSC
O_Jog_FWD_DNZn BOOL 4:0184 10 Jog Forward for Local Downstream Zone
O_Jog_FWD_UpZn BOOL 4:0104 10 Jog Forward for Local Upstream Zone
O_Jog_REV_DNZn BOOL 4:0184 11 Jog Reverse for Local Downstream Zone
O_Jog_REV_UPZn BOOL 4:0104 11 Jog Reverse for Local Upstream Zone
O_Maintenance_Stop_DnZn BOOL 4:0184 13 Force Stop Local Downstream Zone
O_Maintenance_Stop_UpZn BOOL 4:0104 13 Force Stop Local Upstream Zone
O_Release_DnZn BOOL 4:0105 AOI Logic Release and Accumulate on Next at Downstream Zone – Automatically increments release counter
O_Release_UpZn BOOL 4:0185 AOI Logic Release and Accumulate on Next at Upstream Zone – Automatically increments release counter
O_Speed_Motor_Left INT 4:0040 - Set Left Motor Speed Reference
O_Speed_Motor_Right INT 4:0064 - Set Right Motor Speed Reference
O_Sts_DnZn_Discharge_FWD INT 4:0232 - Set Downstream Discharge Zone Forward Status Value
O_Sts_DnZn_Discharge_REV INT 4:0232 - Set Downstream Discharge Zone Reverse Status Value
O_Sts_UpZn_Induct_FWD INT 4:0134 - Set Upstream Induct Zone Forward Status Value
O_Sts_UpZn_Induct_REV INT 4:0134 - Set Upstream Induct Zone Reverse Status Value
O_Tracking_DnZn DINT 4:0212 (MSW) 4:0213 (LSW) AOI Logic Write 32 Bit Tracking Data for Local DnZn When Accumulated
O_Tracking_UpZn DINT 4:0139 (MSW) 4:0140 (LSW) AOI Logic Write 32 Bit Tracking Data for Local DnZn When Accumulated
O_Tracking_Induct_FWD DINT 4:0237 (MSW) 4:0238 (LSW) AOI Logic Set Forward Induct Tracking Value
O_Tracking_Induct_REV DINT 4:0132 (MSW) 4:0133 (LSW) AOI Logic Set Reverse Induct Tracking Value
O_WakeUp_DNZn BOOL 4:0184 12 Wakeup Local Downstream Zone
O_WakeUp_UPZn BOOL 4:0104 12 Wakeup Local Upstream Zone