PLC Developers Guide / ZPA Mode Control / PLC Outputs for ZPA Mode / Speed Control /
Conveylinx-ECO
Speed Control |
ConveyLinx ERSC ❌ | ConveyLinx-Ai 24V ❌ | ConveyLinx-Ai 48V ❌ |
![]() |
|
|
|
| ConveyLinx-ECO ✅ | ZPA Mode ✅ | PLC I/O Mode ❌ | |
![]() |
![]() |
|
| Register Name | Internal Address | Assembled PLC Address | Description | ||
| Set Left Motor Speed | 4:0040 | M: 4:1606 E: O.Data [6] P: Byte 12 (Hi) P: Byte 13 (Lo) |
Integer Value | ||
| Set Left Motor Speed in 0.1% Increments of Max PWM | |||||
| Range: | Range: 0 to 1000 | ||||
| 0 = | Remain at last non-zero value entered | ||||
| Example: 400 = 40% of Max PWM | |||||
| Set Right Motor Speed | 4:0064 | M: 4:1607 E: O.Data [7] P: Byte 14 (Hi) P: Byte 15 (Lo) |
Integer Value | ||
| Set Right Motor Speed in 0.1% Increments of Max PWM | |||||
| Range: | Range: 0 to 1000 | ||||
| 0 = | Remain at last non-zero value entered | ||||
| Example: 400 = 40% of Max PWM | |||||