PLC Developers Guide / PLC I/O Mode Control / PLC Inputs for PLC I/O Mode /
Motor Ports Digital Status |
ConveyLinx ERSC ✅ | ConveyLinx-Ai 24V ✅ | ConveyLinx-Ai 48V ✅ |
![]() |
|
|
|
| ConveyLinx-ECO ✅ | ZPA Mode ❌ | PLC I/O Mode ✅ | |
![]() |
![]() |
|
| Register Name | Internal Address | Assembled PLC Address | Description | ||
| Left Motor Port Digital I/O Status |
4:0060 | M: 4:1712 E: I.Data [12] P: Byte 24 (Hi) P: Byte 25 (Lo) |
Bitwise Value | ||
| Bit 12 = | Short Circuit Error on one or more coil output pins | ||||
| Bit 14 = | Over Current – More than 1A detected on one or more coil output pins | ||||
| All other Bits reserved | |||||
| Right Motor Port Digital I/O Status |
4:0084 | M: 4:1713 E: I.Data [13] P: Byte 26 (Hi) P: Byte 27 (Lo) |
Bitwise Value | ||
| Bit 12 = | Short Circuit Error on one or more coil output pins | ||||
| Bit 14 = | Over Current – More than 1A detected on one or more coil output pins | ||||
| All other Bits reserved | |||||





