PLC Developers Guide / PLC I/O Mode Control / PLC Outputs for PLC I/O Mode /


ConveyStop Command & Clear Motor Error

ConveyLinx ERSC ConveyLinx-Ai 24V ConveyLinx-Ai 48V
ConveyLinx-ECO ZPA Mode PLC I/O Mode

Register Name Internal Address Assembled PLC Address Description
ConveyStop Command 4:0020 M: 4:1800
E: O.Data [0]
P: Byte 0 (Hi)
P: Byte 1 (Lo)
Integer Value
0 = No Command
1 = Command local module’s Stop Group to go to Stopped State
2 = Command local module’s Stop Group to Clear Stopped State
Clear Motor Error 4:0022 M: 4:1816
E: O.Data [16]
P: Byte 32 (Hi)
P: Byte 33 (Lo)
Integer Value
1 = Send Reset command
0 = Clear Reset command

Learn more about Clear Motor Error