PLC Developers Guide / PLC I/O Mode Control / PLC Outputs for PLC I/O Mode /
ConveyStop Command & Clear Motor Error |
ConveyLinx ERSC ✅ | ConveyLinx-Ai 24V ✅ | ConveyLinx-Ai 48V ✅ |
ConveyLinx-ECO ✅ | ZPA Mode ❌ | PLC I/O Mode ✅ | |
Register Name | Internal Address | Assembled PLC Address | Description | ||
ConveyStop Command | 4:0020 | M: 4:1800 E: O.Data [0] P: Byte 0 (Hi) P: Byte 1 (Lo) |
Integer Value | ||
0 = | No Command | ||||
1 = | Command local module’s Stop Group to go to Stopped State | ||||
2 = | Command local module’s Stop Group to Clear Stopped State | ||||
Clear Motor Error | 4:0022 | M: 4:1816 E: O.Data [16] P: Byte 32 (Hi) P: Byte 33 (Lo) |
Integer Value | ||
1 = | Send Reset command | ||||
0 = | Clear Reset command |