PLC Developers Guide / ZPA Mode Control / PLC Inputs for ZPA Mode


Forward and Reverse Tracking

ConveyLinx ERSC ConveyLinx-Ai 24V ConveyLinx-Ai 48V
ConveyLinx-ECO ZPA Mode PLC I/O Mode


Register Name Internal Address Assembled PLC Address Description
Get Tracking
Forward Direction
Word 1
4:0201 M: 4:1514
E: I.Data [14]
P: Byte 28 (Hi)
P: Byte 29 (Lo)
When discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #1 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in default or “forward” direction
Get Tracking
Forward Direction
Word 2
4:0202 M: 4:1515
E: I.Data [15]
P: Byte 30 (Hi)
P: Byte 31 (Lo)
When discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #2 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in default or “forward” direction
Get Tracking
Reverse Direction
Word 1
4:0121 M: 4:1516
E: I.Data [16]
P: Byte 32 (Hi)
P: Byte 33 (Lo)
When discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #1 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in opposite of default or “reverse” direction
Get Tracking
Reverse Direction
Word 2
4:0122 M: 4:1517
E: I.Data [17]
P: Byte 34 (Hi)
P: Byte 35 (Lo)
When discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #2 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in opposite of default or “reverse” direction