PLC Developers Guide / ZPA Mode Control / PLC Inputs for ZPA Mode


ConveyStop Status

ConveyLinx ERSC ConveyLinx-Ai 24V ConveyLinx-Ai 48V
ConveyLinx-ECO ZPA Mode PLC I/O Mode


Register Name Internal Address Assembled PLC Address Description
Reserved M: 4:1519
E: I.Data [19]
P: Byte 38 (Hi)
P: Byte 39 (Lo)
Used for Reset Protection connection
See topic Assemblies with Reset Protection for details
ConveyStop Status 4:0019 M: 4:1520
E: I.Data [20]
P: Byte 40 (Hi)
P: Byte 41 (Lo)
Bitwise Value
bit 00 thru bit 04 – Reserved
bit 05 = Stop active on another module in Stop Group
bit 06 = Stop active due to lost communication connection
bit 07 = Stop active due to lost PLC connection
bit 08 = Reserved
bit 09 = Reserved
bit 10 = Stop active due to Stop Command from PLC
bit 00 thru bit 04 – Reserved