PLC Developers Guide / ZPA Mode Control / PLC Outputs for ZPA Mode / Set Outputs /
ConveyLinx-Ai Family
Set Port Outputs |
ConveyLinx ERSC ❌ | ConveyLinx-Ai 24V ✅ | ConveyLinx-Ai 48V ✅ |
ConveyLinx-ECO ❌ | ZPA Mode ✅ | PLC I/O Mode ❌ | |
Register Name | Internal Address | Assembled PLC Address | Description | ||
Set Aux I/O Outputs | 4:0063 | M: 4:1617 E: O.Data [17] P: Byte 34 (Hi) P: Byte 35 (Lo) |
Bitwise Value | ||
bit 08 = | Left Aux I/O (Pin 2) Usage: 0 = Use as Input / 1 = Use as Output |
||||
bit 09 = | Right Aux I/O (Pin 2) Usage: 0 = Use as Input / 1 = Use as Output |
||||
bit 12 = | Left Aux I/O (Pin 2) as Output: 1 = ON, 0 = OFF (only if bit 08 is ON) |
||||
bit 13 = | Right Aux I/O (Pin 2) as Output: 1 = ON, 0 = OFF (only if bit 09 is ON) |
||||
All other Bits reserved |
Aux I/O Outputs for ConveyLinx-Ai Family
In certain applications, it may be desired to have the PLC actuate a device along the conveyor (i.e. illuminate a light or energize a solenoid coil, etc.). With the ConveyLinx network this can be done without installing a separate PLC I/O system to do this. Refer to either the EasyRoll+ or EasyRoll documentation on how to configure the Aux I/O output.