PLC Developers Guide / PLC I/O Mode Control / PLC Inputs for PLC I/O Mode /
ConveyStop Status |
ConveyLinx ERSC ✅ | ConveyLinx-Ai 24V ✅ | ConveyLinx-Ai 48V ✅ |
ConveyLinx-ECO ✅ | ZPA Mode ❌ | PLC I/O Mode ✅ | |
Register Name | Internal Address | Assembled PLC Address | Description | ||
ConveyStop Status | 4:0019 | M: 4:1700 E: I.Data [0] P: Byte 0 (Hi) P: Byte 1 (Lo) |
Bitwise Value | ||
Bit 00 = | Reserved | ||||
Bit 01 = | Reserved | ||||
Bit 02 = | Reserved | ||||
Bit 03 = | Reserved | ||||
Bit 04 = | Reserved | ||||
Bit 05 = | Stop Active on another module in Stop Group | ||||
Bit 06 = | Stop Active due to lost communication connection | ||||
Bit 07 = | Stop Active due to lost PLC connection | ||||
Bit 08 = | Stop active on Left Control Port | ||||
Bit 09 = | Stop active on Right Control Port | ||||
Bit 10 = | Stop Active due to lost PLC connection | ||||
Bit 11 = | Reserved | ||||
Bit 12 = | Reserved | ||||
Bit 13 = | Reserved | ||||
Bit 14 = | Reserved | ||||
Bit 15 = | Reserved |