Inputs to PLC

Module Address Register Name Ethernet I/P Tag Modbus PLC Holding Register
4:0035 Sensor & Control Port Inputs E: I.Data [0] M: 4:4700
4:0036 Sensor Detect E: I.Data [1] M: 4:4701
4:0057 Left Motor Temperature E: I.Data [2] M: 4:4702
4:0058 Left Motor Status E: I.Data [3] M: 4:4703
4:0081 Right Motor Temperature E: I.Data [4] M: 4:4704
4:0082 Right Motor Status E: I.Data [5] M: 4:4705
4:0060 Left Motor Port Digital I/O Status E: I.Data [6] M: 4:4706
4:0084 Right Motor Port Digital I/O Status E: I.Data [7] M: 4:4707
N/A Current Module Reset Count E: I.Data [8] M: 4:4708

Outputs from PLC

Module Address Register Name Ethernet I/P Tag Modbus PLC Holding Register
4:0060 Set Left Motor Port Digital Control E: O.Data [0] M: 4:4800
4:0084 Set Right Motor Port Digital Control E: O.Data [1] M: 4:4801
4:0037 Control Port Digital Output Control E: O.Data [2] M: 4:4802
4:0260 Left Motor Run / Reverse E: O.Data [3] M: 4:4803
4:0270 Right Motor Run / Reverse E: O.Data [4] M: 4:4804
4:0040 Left Motor Speed Reference E: O.Data [5] M: 4:4805
4:0064 Right Motor Speed Reference E: O.Data [6] M: 4:4806
4:0022 Clear Motor Error E: O.Data [7] M: 4:4807
N/A Set Module Reset Count E: O.Data [8] M: 4:4808