The optional eliminator filter (C2) consists of a single electrolytic capacitor with two (2) wires connected directly to the Power Board (A2).

Preparation:

  • Shut down and lock out all power to ATevo.
  • Remove safety shield and check with a voltmeter.
  • Locate the ‘blue can’ capacitor (C2), at the bottom-left of ATevo, secured to the galvanized base with two (2) nylon zip ties.

Removal of Existing Capacitor:

  • Cut the plastic ties and disconnect wires from the Power Board (A2).
  • Remove the wired capacitor. Replacement capacitor (C2) is supplied with new wires and pre-crimped terminals.

Installation of Replacement Capacitor Assembly:

  • Connect wires of new capacitor assembly (C2) to Power Board.
  • Mount replacement cap to ATevo base with provided wire ties.
  • Replace safety shield, and close front panel door.
  • Restart ATevo.
Last modified: 2 August 2023

Need more help with this?
Don’t hesitate to contact us here.

Thanks for your feedback.