PLC Developers Guide / ZPA Mode Control / PLC Outputs for ZPA Mode / Speed Control /
ConveyLinx-Ai Family
Speed Control |
ConveyLinx ERSC ❌ | ConveyLinx-Ai 24V ✅ | ConveyLinx-Ai 48V ✅ |
ConveyLinx-ECO ❌ | ZPA Mode ✅ | PLC I/O Mode ❌ | |
Register Name | Internal Address | Assembled PLC Address | Description | ||
Set Left Motor Speed | 4:0040 | M: 4:1606 E: O.Data [6] P: Byte 12 (Hi) P: Byte 13 (Lo) |
Integer Value | ||
● For MDR’s: value = mm/sec | |||||
MDR Example: 400 = 0.4 m/sec | |||||
● For PGD’s: value = RPM x 10 | |||||
PGD Example: 400 = 40 RPM | |||||
0 = Remain at last non-zero value entered | |||||
Set Right Motor Speed | 4:0064 | M: 4:1607 E: O.Data [7] P: Byte 14 (Hi) P: Byte 15 (Lo) |
Integer Value | ||
● For MDR’s: value = mm/sec | |||||
MDR Example: 400 = 0.4 m/sec | |||||
● For PGD’s: value = RPM x 10 | |||||
PGD Example: 400 = 40 RPM | |||||
0 = Remain at last non-zero value entered |