ConveyLinx Module status is indicated by several LED’s. All LED’s with the exception of the Ethernet Link and Activity LEDs are multi-colored and context sensitive. The following sections indicate the various meanings of all LED indicators.
If you need help finding where LED Items are located on the ConveyLinx Module
Communications
Indicator | Item | LED State | Description |
---|---|---|---|
Ethernet Left Link | OFF | No connection established | |
Solid Green | Connection is established | ||
Blinking Green | When data transmission activity is occurring | ||
Ethernet Right Link | OFF | No connection established | |
Solid Green | Connection is established | ||
Blinking Green | When data transmission activity is occurring |
Motors
Indicator | Item | LED State | Description |
---|---|---|---|
Motor Left & Motor Right | & | OFF | Motor is not running and no faults detected |
Solid Green | Motor is running | ||
Flashing Green (intermittent) | Motor is being moved or rotated by external force | ||
Solid Red | Motor is not connected or motor is stalled | ||
Blinking Red | Motor is overloaded or over-heated | ||
Flashing Red | Motor Stopped: Short circuit detected between at least two of the phase windings | ||
Motor Running: Over-current condition |
Network & Module Status
Indicator | Item | LED State | Description |
---|---|---|---|
Module Status | Solid Red | Module is booting up or during Auto-Replacement procedure, module is attempting to retrieve data from neighbor module(s) | |
Blinking Red | Module is starting task processes or if already started, indicates that an already established remote controller connection has been lost | ||
Blinking Green | Module is ready | ||
Flashing Green & Blinking Red | Auto-replace procedure has been properly triggered | ||
Flashing Red & Blinking Green | Failsafe Mode | ||
Flashing Red | Auto Configure Mode is active | ||
Blinking Amber | Performing firmware upgrade check | ||
Solid Amber | Firmware upgrade in progress | ||
Network Status | Solid Red | Starting Inter-module communications | |
Blinking Red | Establishing inter-module connections or if already established, an already established inter-module connection has been lost | ||
Blinking Green | Inter-module communications established |
Sensors
Indicator | Item | LED State | Description |
---|---|---|---|
Sensor Left & Right | & | Solid Green | Sensor is Blocked |
Solid Red | Sensor Error State (Pin 3) is Active | ||
Blinking Red | Arrival Jam or missing sensor | ||
Blinking Green/Amber | Sensor Jam | ||
Flashing Green | When Sensor is blocked, indicates external device (PLC/PC controller or EasyRoll) has accumulated the zone and inhibiting release |
Control Ports
Indicator | Item | LED State | Description |
---|---|---|---|
Control Port Left & Right | & | Solid Green | If acting as Upstream Port: Wake-up signal is logically enabled on Pin 4 |
If acting as Downstream Port: Lane Full signal is logically enabled | |||
If Module is in PLC I/O Mode: Signal on Pin 4 is logically enabled | |||
Solid Red | Local Accumulate signal (Pin 3) is logically enabled | ||
Flashing Red | Module configuration error |
Special Cases
Indicator | Item | LED State | Description |
---|---|---|---|
All Sensor, Control Port & Motor | Flashing Red | Module in stopped state | |
Left Sensor, Left Control Port, & Left Motor | Flashing Green | ZPA zone on left side of module is in Maintenance Mode* | |
Right Sensor, Right Control Port, & Right Motor | Flashing Green | ZPA zone on right side of module is in Maintenance Mode* |