Module Address Register Name Assembled Address for FW 5.2 Assembled Address for FW 4.25 and earlier
4:0132 Set Local Upstream Zone Tracking Word 1 4:11600 4:1600
4:0133 Set Local Upstream Zone Tracking Word 2 4:11601 4:1601
4:0212 Set Local Downstream Zone Tracking Word 1 4:11602 4:1602
4:0213 Set Local Downstream Zone Tracking Word 2 4:11603 4:1603
4:0104 Accumulation Control for Local Upstream Zone 4:11604 4:1604
4:0184 Accumulation Control for Local Downstream Zone 4:11605 4:1605
4:0040 Set Left MDR Speed 4:11606 4:1606
4:0064 Set Right MDR Speed 4:11607 4:1607
4:0105 Release and Accumulate on Next Arrival for Local Upstream Zone 4:11608 4:1608
4:0185 Release and Accumulate on Next Arrival for Local Downstream Zone 4:11609 4:1609
4:0134 Set Status for Upstream Induct 4:11610 4:1610
4:0232 Set Status for Downstream Discharge 4:11611 4:1611
4:0139 Set Induct Tracking Forward Direction Word 1 4:11612 4:1612
4:0140 Set Induct Tracking Forward Direction Word 2 4:11613 4:1613
4:0237 Set Induct Tracking Reverse Direction Word 1 4:11614 4:1614
4:0238 Set Induct Tracking Forward Direction Word 2 4:11615 4:1615
4:0022 Clear Motor Error 4:11616 4:1616
4:0063 Set Control Port Outputs 4:11617 4:1617
N/A Reserved 4:11618 4:1618
4:0020 ConveyStop Command 4:11619 4:1619
4:0109 Clear Sensor Jam Command for Local Upstream Zone 4:11620 4:1620
4:0189 Clear Sensor Jam Command for Local Downstream Zone 4:11621 4:1621
4:0365 Direction & Accumulation Mode Control for Local Upstream Zone 4:11622 4:1622
4:0375 Direction & Accumulation Mode Control for Local Downstream Zone 4:11623 4:1623
4:0387 ConveyMerge Interface 4:11624 4:1624