Spraying Simulation screen is used to perform various tests of the sprayer implement components, with the equipment outside its normal spraying operation and in a stationary position. Below a short list of test that can be performed through this screen.
- Flowmeter Calibration
- Nozzle tests
- Adjusting the calibrated return – for 3-way Section Valves
- Miscellaneous diagnosis
The image below shows the Spraying Simulation screen, detailing each item in its composition.
Item | Description |
---|---|
Target Rate | Fixed target rate at which simulation will occur, editable by the button
|
Speed | Machine speed to perform the simulation, editable by the button
|
Rate | Rate in L/ha read from the spraying system, considering the Flowmeter Constant currently configured. |
Flow | Flow in L/min of the spraying system, considering the Flowmeter Constant currently configured.
|
Spraying | Main spraying switch status – Off or On. The status can be changed by Application Button, or by the touch sensitive button to switch on the spraying |
Flowmeter | Value of pulses/min read from the flow meter.
|
Implement Sensor | Implement Sensor configuration status – Able or Disabled. |
Section switch buttons | Touch sensitive buttons for operating the sections, at the bottom of the Spraying Simulation screen. The width of the buttons depends on currently configurated sections number – 1 to 9. The buttons can assume the following states.
|