Spraying Simulation screen is used to perform various tests of the sprayer implement components, with the equipment outside its normal spraying operation and in a stationary position. Below a short list of test that can be performed through this screen.

The image below shows the Spraying Simulation screen, detailing each item in its composition.

Item Description
Target Rate Fixed target rate at which simulation will occur, editable by the button . A rate value should be selected close to what will be used for effective spraying operation in the field.
  • Screen type = Value editing
  • Decimal places = None
  • Minimum value = 10 L/ha
  • Maximum value = 1000 L/ha
Speed Machine speed to perform the simulation, editable by the button . A speed value selected must be close to that used in the effective spraying work in the field.
  • Screen type = Value editing
  • Decimal places = 1
  • Minimum value = 1.0 km/h
  • Maximum value = 150.0 km/h
Rate Rate in L/ha read from the spraying system, considering the Flowmeter Constant currently configured.
Flow Flow in L/min of the spraying system, considering the Flowmeter Constant currently configured.
Spraying Main spraying switch status – Off or On. The status can be changed by Application Button, or by the touch sensitive button to switch on the spraying .
Flowmeter Value of pulses/min read from the flow meter.
  • This value must be used to diagnose whether the flowmeter is operating correctly.
Implement Sensor Implement Sensor configuration status – Able or Disabled.
Section switch buttons Touch sensitive buttons for operating the sections, at the bottom of the Spraying Simulation screen. The width of the buttons depends on currently configurated sections number – 1 to 9. The buttons can assume the following states.
  • – Section open and applying
  • – Section open and not applying
  • – Closed section