The cable and monitor connectors IsoView they have labels that easily identify the correct connections that must be made. Just connect the connectors identified with the same inscription for correct installation.

Installing the monitor and antenna GNSS

The following figure illustrates the necessary connections of the set of items for installing the monitor IsoView and the antenna GNSS on the tractor.

Item description
Monitor IsoView
Antenna cable GNSS
Antenna GNSS
Monitor power cable
Connection cable with battery, with fuse holder
Battery 12 V

Connecting the monitor to the spray cable

Monitor connections IsoView spray cable follow the diagram shown in the figure below.

Item description
Monitor IsoView
Cab spray cable
Spray cable extender
Implement spray cable

Connecting the spray cable to the implement

There are several spray implement configurations, according to the valve model, number of sections, presence of regulating valve, general valve, flow meter and other sensors. For each configuration it is possible to have a different cable kit, using the items described in System Components.

The following are some examples of system configurations IsoView for spraying.

Example 1: Bar sprayer, low current 2-wire valves, connectors DIN 43650-B

  • 72-wire Section Valves DIN 43650-B
  • General Valve 2 wires DIN 43650-B
  • 2-wire Regulating Valve DIN 43650-B
  • 3-way Superseal Amp Flowmeter

Item description
Implement spray cable
Buffer connector for power input
9x Terminator cable for valves with model connector DIN 43650-B
7x Section 2 valve wires connector DIN 43650-B
Regulator Valve 2 wires connector DIN 43650-B
General Valve 2-wire connector DIN 43650-B
3-way Superseal Amp Connector Flowmeter
2x Buffer connector for valve outlet
4x Buffer connector for sensor input

Example 2: Bar sprayer, high current 2-wire valves, Delphi connectors

  • 92-way Delphi high current Section valves
  • 2-way high current Delphi General Valve
  • 4-way Delphi high current regulating valve
  • Delphi 3-way flow meter

Item description
Implement spray cable
Power cable for 3-wire or high-current valves
Battery 12 V
11x Cable with relays for actuation of 3-wire or high-current valves
Terminator cable for valves with Delphi 4-way connector
10 x Valve terminator cable with 2-way Delphi connector
9x High current Delphi connector 2-way Section Valve
High current Delphi connector 4-way regulating valve
General Valve for high current Delphi connector 2 ways
Terminator cable for sensors with Delphi 3-way connector
Delphi 3-way connector flow meter
4x Buffer connector for sensor input

Example 3: Atomizer for fruit growing, high current solenoid valves, and ultrasonic sensors

  • 2Section valves with high current solenoid DIN 43650
  • 2Ultrasonic sensors for fruit growing M12 5-way

Item description
Implement spray cable
Power cable for 3-wire or high-current valves
Battery 12 V
2x Cable with relays for actuation of 3-wire or high-current valves
2x Terminator cable for valves with model connector DIN 43650
2x Section valve with high current solenoid connector DIN 43650
2x Terminator cable for ultrasonic sensors with 5-way M12 connector
2x Ultrasonic sensor for fruit growing M12 5 way connector
9x Buffer connector for valve outlet
3x Buffer connector for sensor input