*Screen type = Value editing
*Decimal places = None
Minimum value = 100 L
Maximum value = 50000 L
Tank Capacity parameter value tells the IsoView system the total volume of the sprayer implement tank. From the configured value, the system is able to show the current tank level during application and notify the user through Level Alarm when the fluid is about to finish.
The following image shows Tank Capacity parameter setting screen.
*The IsoView system does not have an analog tank level sensor, so calculation is made based on the initial level informed by the user when filling up or changing the level of the tank on the navigation screen, decreasing the amount of fluid that passed through the flowmeter so far. In order for the calculation to be performed as accurately as possible is important that Flowmeter Calibration is done properly.