Module Address Register Name Assembled Address for FW 5.2 Assembled Address for FW 4.25 and earlier
4:0020 ConveyStop Command 4:31800 4:3800
4:0060 Set Left Motor Port Digital Control 4:31801 4:3801
4:0084 Set Right Motor Port Digital Control 4:31802 4:3802
4:0037 Control Port Digital Output Control 4:31803 4:3803
4:0260 Left Motor Run / Reverse 4:31804 4:3804
4:0261 Left Motor Brake Method 4:31805 4:3805
4:0262 Left Motor Speed Control Method 4:31806 4:3806
4:0270 Right Motor Run / Reverse 4:31807 4:3807
4:0271 Right Motor Brake Method 4:31808 4:3808
4:0272 Right Motor Speed Control Method 4:31809 4:3809
4:0040 Left Motor Speed Reference 4:31810 4:3810
4:0064 Right Motor Speed Reference 4:31811 4:3811
4:0043 Left Motor Acceleration Ramp 4:31812 4:3812
4:0044 Left Motor Deceleration Ramp 4:31813 4:3813
4:0067 Right Motor Acceleration Ramp 4:31814 4:3814
4:0068 Right Motor Deceleration Ramp 4:31815 4:3815
4:0022 Clear Motor Error 4:31816 4:3816
4:0196 Set Status to Downstream Module 4:31817 4:3817
4:0116 Set Status to Upstream Module 4:31818 4:3818
4:0034 Sensor Port Input Signal Condition Mask 4:31819 4:3819
4:0201 Set Discharge Tracking Word 1 4:31820 4:3820
4:0202 Set Discharge Tracking Word 2 4:31821 4:3821
N/A Set Module Reset Count 4:31822 4:3822
4:0008 Left Motor Servo Command Pulses 4:31823 4:3823
4:0009 Left Motor Servo Command Word 4:31824 4:3824
4:0013 Right Motor Servo Command Pulses 4:31825 4:3825
4:0014 Right Motor Servo Command Word 4:31826 4:3826