This Assembly contains the output from the PLC that is provided as input to the ERSC when in ZPA Mode.
Register Name / Module Address | Assembled Address for PLC | Links |
---|---|---|
Set Local Upstream Zone Tracking Word 1 4:0132 |
M: 4:1600 E: O.Data[0] P: Byte 0 (Hi) Byte 1 (Lo) |
Set Local Tracking |
Set Local Upstream Zone Tracking Word 2 4:0133 |
M: 4:1601 E: O.Data[1] P: Byte 2 (Hi) Byte 3 (Lo) |
Set Local Tracking |
Set Local Downstream Zone Tracking Word 1 4:0212 |
M: 4:1602 E: O.Data[2] P: Byte 4 (Hi) Byte 5 (Lo) |
Set Local Tracking |
Set Local Downstream Zone Tracking Word 2 4:0213 |
M: 4:1603 E: O.Data[3] P: Byte 6 (Hi) Byte 7 (Lo) |
Set Local Tracking |
Accumulation Control for Local Upstream Zone 4:0104 |
M: 4:1604 E: O.Data[4] P: Byte 8 (Hi) Byte 9 (Lo) |
Accumulation Control |
Accumulation Control for Local Downstream Zone 4:0184 |
M: 4:1605 E: O.Data[5] P: Byte 10 (Hi) Byte 11 (Lo) |
Accumulation Control |
Set Left MDR Speed 4:0040 |
M: 4:1606 E: O.Data[6] P: Byte 12 (Hi) Byte 13 (Lo) |
Speed Control |
Set Right MDR Speed 4:0064 |
M: 4:1607 E: O.Data[7] P: Byte 14 (Hi) Byte 15 (Lo) |
Speed Control |
Release and Accumulate on Next Arrival for Local Upstream Zone 4:0105 |
M: 4:1608 E: O.Data[8] P: Byte 16 (Hi) Byte 17 (Lo) |
Release and Status |
Release and Accumulate on Next Arrival for Local Downstream Zone 4:0185 |
M: 4:1609 E: O.Data[9] P: Byte 18 (Hi) Byte 19 (Lo) |
Release and Status |
Set Status for Upstream Induct 4:0134 |
M: 4:1610 E: O.Data[10] P: Byte 20 (Hi) Byte 21 (Lo) |
Release and Status |
Set Status for Downstream Discharge 4:0232 |
M: 4:1611 E: O.Data[11] P: Byte 22 (Hi) Byte 23 (Lo) |
Release and Status |
Set Induct Tracking Forward Direction Word 1 4:0139 |
M: 4:1612 E: O.Data[12] P: Byte 24 (Hi) Byte 25 (Lo) |
Induct Tracking Forward and Reverse |
Set Induct Tracking Forward Direction Word 2 4:0140 |
M: 4:1613 E: O.Data[13] P: Byte 26 (Hi) Byte 27 (Lo) |
Induct Tracking Forward and Reverse |
Set Induct Tracking Reverse Direction Word 1 4:0237 |
M: 4:1614 E: O.Data[14] P: Byte 28 (Hi) Byte 29 (Lo) |
Induct Tracking Forward and Reverse |
Set Induct Tracking Forward Direction Word 2 4:0238 |
M: 4:1615 E: O.Data[15] P: Byte 30 (Hi) Byte 31 (Lo) |
Induct Tracking Forward and Reverse |
Clear Motor Error 4:0022 |
M: 4:1616 E: O.Data[16] P: Byte 32 (Hi) Byte 33 (Lo) |
Set Outputs and Motor Clear |
Set Control Port Outputs 4:0063 |
M: 4:1617 E: O.Data[17] P: Byte 34 (Hi) Byte 35 (Lo) |
Set Outputs and Motor Clear |
Reserved N/A |
M: 4:1618 E: O.Data[18] P: Byte 36 (Hi) Byte 37 (Lo) |
|
ConveyStop Command 4:0020 |
M: 4:1619 E: O.Data[19] P: Byte 38 (Hi) Byte 39 (Lo) |
ConveyStop and Clear Jams |
Clear Sensor Jam Command for Local Upstream Zone 4:0109 |
M: 4:1620 E: O.Data[20] P: Byte 40 (Hi) Byte 41 (Lo) |
ConveyStop and Clear Jams |
Clear Sensor Jam Command for Local Downstream Zone 4:0189 |
M: 4:1621 E: O.Data[21] P: Byte 42 (Hi) Byte 43 (Lo) |
ConveyStop and Clear Jams |
Direction & Accumulation Mode Control for Local Upstream Zone 4:0365 |
M: 4:1622 E: O.Data[22] P: Byte 44 (Hi) Byte 45 (Lo) |
Direction and Accumulation Mode |
Direction & Accumulation Mode Control for Local Downstream Zone 4:0375 |
M: 4:1623 E: O.Data[23] P: Byte 46 (Hi) Byte 47 (Lo) |
Direction and Accumulation Mode |
ConveyMerge Interface 4:0387 |
M: 4:1624 E: O.Data[24] P: Byte 48 (Hi) Byte 49 (Lo) |
ConveyMerge Interface |