Register Name / Module Address Assembled Address for PLC Description
Get Tracking Forward Direction Word 1
4:0201
M: 4:1514
E: I.Data [14]
P: Byte 28 (Hi)
   Byte 29 (Lo)
When ERSC is discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #1 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in default or “forward” direction
Get Tracking Forward Direction Word 2
4:0202
M: 4:1515
E: I.Data [15]
P: Byte 30 (Hi)
   Byte 31 (Lo)
When ERSC is discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #2 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in default or “forward” direction
Get Tracking Reverse Direction Word 1
4:0121
M: 4:1516
E: I.Data [16]
P: Byte 32 (Hi)
   Byte 33 (Lo)
When ERSC is discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #1 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in opposite of default or “reverse” direction
Get Tracking Reverse Direction Word 2
4:0122
M: 4:1517
E: I.Data [17]
P: Byte 34 (Hi)
   Byte 35 (Lo)
When ERSC is discharging to Non-ConveyLinx controlled conveyor:
Value = Tracking data word #2 (16-bit integer) for the Carton that has just discharged from the local downstream zone when local conveyor is operating in opposite of default or “reverse” direction