Steps:

  • Shut down and lock out all power to ATevo.
  • Remove safety shield.
  • The 9V DC Power Supply Board (P/S-A2) is plugged onto the bottom-center of Power Board (A2), directly below the L2-2 lug.
  • Gently pull the DC Power Supply Board off of the Power Board.
  • Align the two (2) header sockets (on bottom of the replacement DC Power Supply Board) with the J101 and J102 header pin strips on the existing Power Board.
  • Gently press the new DC Power Supply Board (P/S-A2) onto Power Board (A2) until it mates.
  • Replace safety shield, and close the front panel door.
  • Restart ATevo.