Trigger message type (p26)

Set the type of log record which is generated when the trigger is pressed.
Format:
     T Trident type
     I IPICO type – looks like abA000001609280011093907000200
     E Extened type – like IPICO type but can have a description string appended to the end
Default: I
Example: Trigger message type=I

Trigger edge (p33)

A single character which controls which edge(s) of the trigger the reader should respond to.
Normally the trigger responds when it is first pressed (falling) but it can be setup to respond when released (rising) or on both edges (both).
Format: Falling, Rising, Both
Default: F
Can be set at any time.
Example: Trigger edge=F

Trigger filter time

When zero, don’t do any filtering of the trigger input.
When larger than zero, it is the number of centiseconds (1/100 of a second) to ignore the trigger event following the previous trigger event.
Format: Whole number from 0 to 4 billion
Default: 0 – no filtering
Can be set at any time.
Example: Trigger filter time=50 // Ignore any trigger which happens less than 0.5 seconds following the previous trigger

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.