Log raw to SD (p08)

A True/False setting which controls whether to write raw tag reads to the raw.log file on the SD card.
Format: T for true or F for false.
Default: T
Can be set at any time.
Example: Log raw to SD=T
Note: we recommend you always leave this set to true, so you do not need to put this line in your config.ini, you can just leave it set to the default.

Log filtered to SD (p09)

A True/False setting which controls whether to write filtered tag records to the filtered.log file on the SD card.
Format: T for true or F for false.
Default: T
Can be set at any time.
Example: Log filtered to SD=T
Note: we recommend you always leave this set to true, so you do not need to put this line in your config.ini, you can just leave it set to the default.

Log raw to ethernet (p10)

A True/False setting which controls whether to allow raw tag reads to be read from the raw logging port.
Format: T for true or F for false.
Default: T
Can be set at any time.
Example: Log raw to ethernet=T
Note: we recommend you always leave this set to true, so you do not need to put this line in your config.ini, you can just leave it set to the default.

Log filtered to ethernet (p11)

A True/False setting which controls whether to allow filtered tag reads to be read from the filtered logging port.
Format: T for true or F for false.
Default: T
Can be set at any time.
Example: Log filtered to ethernet=T
Note: we recommend you always leave this set to true, so you do not need to put this line in your config.ini, you can just leave it set to the default.

Log filtered to serial (p12)

A True/False setting which controls whether to output filtered tag records on the serial port. In PRO ‘R’,‘XR’,‘XWR’ readers, there is an internal radio connected to the serial port
Format: T for true or F for false.
Default: F
Can be set at any time.
Example: Log filtered to serial=T

Log raw to USB (p38)

A True/False setting which controls whether the reader sends raw reads to the USB com port (if connected and the switch is in the “Data” mode).
Format: T for true or F for false.
Default: F
Can be set at any time.
Example: Log raw to USB=T

Log filtered to USB (p37)

A True/False setting which controls whether the reader sends filtered reads to the USB com port (if connected and the switch is in the “Data” mode).
Format: T for true or F for false.
Default: F
Can be set at any time.
Example: Log filtered to USB=T

Serial output baudrate (p14)

Controls the baudrate of the reader’s serial port.
If using the internal radio of a PRO ‘R’,‘XR’ or ‘XWR’ then this should be left as default.
Format: One of the values 300, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400
Default: 115200
Can be set in config.ini only.
Example: Serial output baudrate=115200