This Assembly contains the output from the ERSC in ZPA Mode that is provided as input to the PLC.

Register Name / Module Address Assembled Address for PLC Links
Local Status Upstream Zone
4:0116
M: 4:1600
E: I.Data[0]
P: Byte 0 (Hi)
   Byte 1 (Lo)
Local Zone Status
Local Status Downstream Zone
4:0196
M: 4:1601
E: I.Data[1]
P: Byte 2 (Hi)
   Byte 3 (Lo)
Local Zone Status
Arrival Count Local Upstream Zone
4:0106
M: 4:1602
E: I.Data[2]
P: Byte 4 (Hi)
   Byte 5 (Lo)
Arrival/Departure Counts
Departure Count Local Upstream Zone
4:0107
M: 4:1603
E: I.Data[3]
P: Byte 6 (Hi)
   Byte 7 (Lo)
Arrival/Departure Counts
Arrival Count Local Downstream Zone
4:0186
M: 4:1604
E: I.Data[4]
P: Byte 8 (Hi)
   Byte 9 (Lo)
Arrival/Departure Counts
Departure Count Local Downstream Zone
4:0187
M: 4:1605
E: I.Data[5]
P: Byte 10 (Hi)
   Byte 11 (Lo)
Arrival/Departure Counts
Module Status Word 1
4:0088
M: 4:1606
E: I.Data[6]
P: Byte 12 (Hi)
   Byte 13 (Lo)
Module Status
Module Status Word 2
4:0089
M: 4:1607
E: I.Data[7]
P: Byte 14 (Hi)
   Byte 15 (Lo)
Module Status
Current Upstream Zone Tracking Word 1
4:0119
M: 4:1608
E: I.Data[8]
P: Byte 16 (Hi)
   Byte 17 (Lo)
Tracking and Release Counts
Current Upstream Zone Tracking Word 2
4:0120
M: 4:1609
E: I.Data[9]
P: Byte 18 (Hi)
   Byte 19 (Lo)
Tracking and Release Counts
Current Downstream Zone Tracking Word 1
4:0199
M: 4:1610
E: I.Data[10]
P: Byte 20 (Hi)
   Byte 21 (Lo)
Tracking and Release Counts
Current Downstream Zone Tracking Word 2
4:0200
M: 4:1611
E: I.Data[11]
P: Byte 22 (Hi)
   Byte 23 (Lo)
Tracking and Release Counts
Current Release Count for Upstream Zone
4:0105
M: 4:1612
E: I.Data[12]
P: Byte 24 (Hi)
   Byte 25 (Lo)
Tracking and Release Counts
Current Release Count for Downstream Zone
4:0185
M: 4:1613
E: I.Data[13]
P: Byte 26 (Hi)
   Byte 27 (Lo)
Tracking and Release Counts
Get Tracking Forward Direction Word 1
4:0201
M: 4:1614
E: I.Data[14]
P: Byte 28 (Hi)
   Byte 29 (Lo)
Forward and Reverse Tracking
Get Tracking Forward Direction Word 2
4:0202
M: 4:1615
E: I.Data[15]
P: Byte 30 (Hi)
   Byte 31 (Lo)
Forward and Reverse Tracking
Get Tracking Reverse Direction Word 1
4:0121
M: 4:1616
E: I.Data[16]
P: Byte 32 (Hi)
   Byte 33 (Lo)
Forward and Reverse Tracking
Get Tracking Reverse Direction Word 2
4:0122
M: 4:1617
E: I.Data[17]
P: Byte 34 (Hi)
   Byte 35 (Lo)
Forward and Reverse Tracking
Sensor & Control Port Inputs
4:0035
M: 4:1618
E: I.Data[18]
P: Byte 36 (Hi)
   Byte 37 (Lo)
Port Inputs and ConveyStop Status
Reserved
N/A
M: 4:1619
E: I.Data[19]
P: Byte 38 (Hi)
   Byte 39 (Lo)
ConveyStop Status
4:0019
M: 4:1620
E: I.Data[20]
P: Byte 40 (Hi)
   Byte 41 (Lo)
Port Inputs and ConveyStop Status