| ConveyLogix Controller Tag | Ethernet I/P Tag | Modbus PLC Holding Register | Profinet I/O Byte Offset |
|---|---|---|---|
| FromPLCArray [0] | E: O.Data [0] | M: 4:13200 | P: Byte 0 (Hi) Byte 1 (Lo) |
| FromPLCArray [1] | E: O.Data [1] | M: 4:13201 | P: Byte 2 (Hi) Byte 3 (Lo) |
| FromPLCArray [2] | E: O.Data [2] | M: 4:13202 | P: Byte 4 (Hi) Byte 5 (Lo) |
| FromPLCArray [3] | E: O.Data [3] | M: 4:13203 | P: Byte 6 (Hi) Byte 7 (Lo) |
| FromPLCArray [4] | E: O.Data [4] | M: 4:13204 | P: Byte 8 (Hi) Byte 9 (Lo) |
| FromPLCArray [5] | E: O.Data [5] | M: 4:13205 | P: Byte 10 (Hi) Byte 11 (Lo) |
| FromPLCArray [6] | E: O.Data [6] | M: 4:13206 | P: Byte 12 (Hi) Byte 13 (Lo) |
| FromPLCArray [7] | E: O.Data [7] | M: 4:13207 | P: Byte 14 (Hi) Byte 15 (Lo) |
| FromPLCArray [8] | E: O.Data [8] | M: 4:13208 | P: Byte 16 (Hi) Byte 17 (Lo) |
| FromPLCArray [9] | E: O.Data [9] | M: 4:13209 | P: Byte 18 (Hi) Byte 19 (Lo) |
| FromPLCArray [10] | E: O.Data [10] | M: 4:13210 | P: Byte 20 (Hi) Byte 21 (Lo) |
| FromPLCArray [11] | E: O.Data [11] | M: 4:13211 | P: Byte 22 (Hi) Byte 23 (Lo) |
| FromPLCArray [12] | E: O.Data [12] | M: 4:13212 | P: Byte 24 (Hi) Byte 25 (Lo) |
| FromPLCArray [13] | E: O.Data [13] | M: 4:13213 | P: Byte 26 (Hi) Byte 27 (Lo) |
| FromPLCArray [14] | E: O.Data [14] | M: 4:13214 | P: Byte 28 (Hi) Byte 29 (Lo) |
| FromPLCArray [15] | E: O.Data [15] | M: 4:13215 | P: Byte 30 (Hi) Byte 31 (Lo) |