Module Address Register Name Ethernet I/P Tag Modbus PLC Holding Register
4:0019 ConveyStop Status E: I.Data [0] M: 4:3700
4:0035 Sensor & Control Port Inputs E: I.Data [1] M: 4:3701
4:0036 Sensor Detect E: I.Data [2] M: 4:3702
4:0024 Module Voltage E: I.Data [3] M: 4:3703
4:0055 Left Motor Current E: I.Data [4] M: 4:3704
4:0056 Left Motor Frequency E: I.Data [5] M: 4:3705
4:0057 Left Motor Temperature E: I.Data [6] M: 4:3706
4:0058 Left Motor Status E: I.Data [7] M: 4:3707
4:0079 Right Motor Current E: I.Data [8] M: 4:3708
4:0080 Right Motor Frequency E: I.Data [9] M: 4:3709
4:0081 Right Motor Temperature E: I.Data [10] M: 4:3710
4:0082 Right Motor Status E: I.Data [11] M: 4:3711
4:0060 Left Motor Port Digital I/O Status E: I.Data [12] M: 4:3712
4:0084 Right Motor Port Digital I/O Status E: I.Data [13] M: 4:3713
4:0134 Upstream Module Status E: I.Data [14] M: 4:3714
4:0232 Downstream Module Status E: I.Data [15] M: 4:3715
4:0139 Current Tracking Word 1 for Adjacent Upstream Module E: I.Data [16] M: 4:3716
4:0140 Current Tracking Word 2 for Adjacent Upstream Module E: I.Data [17] M: 4:3717
N/A Current Module Reset Counter E: I.Data [18] M: 4:3718
4:0062 Left Motor Servo Position E: I.Data [19] M: 4:3719
4:0086 Right Motor Servo Position E: I.Data [20] M: 4:3720
4:0011 Left Motor Servo Status E: I.Data [21] M: 4:3721
4:0016 Right Motor Servo Status E: I.Data [22] M: 4:3722