Air Pressure
  • Excess pressure or vacuum can damage the device.
Attention
  • The SmartMonitor measures the ambient temperature and not the quality of the monitored goods. Its purpose is to signal if product quality evaluation is required.
Automatic flight mode
  • Automatic flight mode may not be activated in all aircraft types. Enable manual flight mode in case of doubt and/or regulation prescribes that radio must be suspended.
Battery
  • The battery cannot be removed or replaced. Check the technical specification for detailed battery information. Contact Berlinger support at support@berlinger.com for refurbishment options.
  • Risk of fire or explosion if the battery is replaced by an incorrect type.
  • Risk of explosion if the battery is disposed of in a fire or hot oven.
  • Leaving the battery in an extremely high temperature surrounding environment can result in an explosion or leakage.
  • Do not subject battery to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
  • Instructions required by IEC 62368-1 regarding coin cells.
Compatibility
  • SmartMonitor device only works in combination with the SmartView software (version 6.0 or higher).
Connectivity
  • Real-time availability of measurements may depend on local connectivity and may be delayed.
Damage
  • If the SmartMonitor device is damaged, don’t use it and contact Berlinger support for refurbishment options.
General
  • Ensure that the user manual instructions are followed before using the SmartMonitor for monitoring. Without proper starting, the measurements will not be available.
Humidity and pressure sensor
  • The SmartMonitor has built-in humidity and atmospheric pressure sensors. The sensors are located on the left side of the device and are covered by white membrane/seal. Keep the membrane clean. Do not push, press, peel-off or pin the white membrane as it will damage the sensors and affect the water tightness.
Ingress Protection
  • IP65: Protect from dust ingress and water spray from any direction.
Liability The manufacturer shall not be held liable.
  • if the device was used beyond the manufacturer’s given limitations.
  • for any claims due to improper storage or use of the device.
  • for any problems with the temperature-controlling and/or -cooling unit.
  • for the quality of any monitored goods.
  • for incorrect readings if the device was used beyond its expiry date.
Light sensor
  • Do not cover the light sensor with any label or tape to ensure the functionality of the light sensor.
Mechanical force
  • Avoid violent shocks and impacts.
Microwave
  • Do not expose the device to microwave radiation (risk of battery explosion).
Multifunctional button
  • Do not apply force as it will damage the button.
Recycling
  • Recycle the product at the end of its lifetime according to local regulations.
Safety
  • Keep away from children.
  • Don’t open it.
  • Berlinger recommends training of all persons that handle the SmartMonitor device and/or SmartView.
Sensor socket (M5)
  • The sensor socket (M5) is a sensitive part of the device.
  • If you are not using the sensor socket (M5), keep it covered to protect from water, dust, etc..
  • When connecting a SmartSensor, take care to align the SmartSensor well with the device to avoid damaging the pins of the sensor socket (M5).
  • Do not apply force as it will damage the connector.
Temperature
  • Temperatures outside the device operating temperature range may damage the device and/or reduce its performance. To learn about the device operating temperature range for each SmartMonitor type, see the information in the technical specification.
X-rays/Röntgen
  • Avoid long-term exposure to X-rays/Röntgen (risk of damaging the device).

Subject to change. Please note that all information in this document is correct at the time of publication. Due to our policy of continuous product development, we reserve the right to change this information without prior notice.

On the back of the SmartMonitor device is a QR-code, which links the SmartMonitor User Manual.

If more help is needed, contact Berlinger support at support@berlinger.com.

Manufactured by:

Berlinger & Co. AG
Mitteldorfstrasse 2
9608 Ganterschwil
SWITZERLAND

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.

Post Comment

Raphaël wrote: Aug 22, 2022

compatibility : indicate SmartView version (6.0 or higher)