The Filtering Board assembly (A7) consists of a capacitor bank (C1x) and bleed resistor (R9x) mounted on a printed circuit board.

Preparation:

  • Shut down and lock out all power to ATevo.
  • Remove safety shield.
  • Locate capacitor board assembly on top of heatsink, above power board and rectifier along left side of ATevo.

Removal of Existing Capacitor Board Assembly:

  • Remove (2) nuts from studs connecting Power Board (A2) to Capacitor Board (A7).
  • Remove (1) screw at top center of Capacitor Board.
  • Remove existing capacitor board assembly.

Installation of New Capacitor Board Assembly:

  • Place new Capacitor Board Assembly (A7) onto studs on Power Board (A2) and replace (2) nuts and (1) screw.
  • Replace safety shield, close front panel door, and restart ATevo.
Last modified: 4 March 2021

Need more help with this?
Don’t hesitate to contact us here.

Thanks for your feedback.