The optional eliminator filter (C2) consists of a single ‘blue can’ electrolytic capacitor with two (2) wires that connect to Power Board.

Preparation:

  • Shut down and lock out all power to ATevo.
  • Remove safety shield.
  • Locate capacitor (C2) at bottom-left of enclosure, mounted with two (2) wires to ATevo base.

Removal of Existing Capacitor:

  • Cut the plastic ties and disconnect wires from the Power Board (A2). Remove the wired capacitor. Replacement capacitor (C2) is supplied with new wires and pre-crimped terminals.

Installation of Replacement Capacitor Assembly:

  • Connect wires of new capacitor assembly (C2) to Power Board.
  • Mount replacement cap to ATevo base with provided wire ties.
  • Replace safety shield, close front panel door, and restart ATevo.