• Shut down and lock out all power to the ATevo.
  • Remove the safety shield.
  • The MOV Board (A9) is bolted to top left side of circuit breaker bracket.
  • Remove the two (2) screws that connect the Transformer (T1) primary wire lugs to the MOV Board (A9).
  • Remove the bolt that mounts the MOV Board (A9) to the breaker bracket.
  • Bolt the new MOV Board (A9) onto the breaker bracket.
  • Install the two (2) screws through the lugs that connect MOV Board to the primary wires and tighten nuts.
  • Replace the safety shield and close the front panel door.
  • Restart the ATevo.
Last modified: 4 March 2021

Need more help with this?
Don’t hesitate to contact us here.

Thanks for your feedback.