Register Name / Module Address | Assembled Address for PLC | Description |
---|---|---|
Sensor & Control Port Inputs 4:0035 |
M: 4:1518 E: I.Data [18] P: Byte 36 (Hi) Byte 37 (Lo) |
Bitwise Value – Read Only: bit 0 = Left Sensor Port – Aux I/O (M8 Pin 2) bit 2 = Right Sensor Port – Aux I/O (M8 Pin 2) bit 4 = Left Sensor Port – Sensor Signal (M8 Pin4) bit 6 = Right Sensor Port – Sensor Signal (M8 Pin 4) bit 15 = 2 sec on / 2 sec off heatbeat All other bits reserved |
Reserved | M: 4:1519 E: I.Data [19] P: Byte 38 (Hi) Byte 39 (Lo) |
|
ConveyStop Status 4:0019 |
M: 4:1520 E: I.Data [20] P: Byte 40 (Hi) Byte 41 (Lo) |
Bitwise Value – Read Only: bit 0 – 4 Reserved bit 5 = Stop active on another module in Stop Group bit 6 = Stop active due to lost communication connection bit 7 = Stop active due to lost PLC connection bit 8 = Stop active on local module’s Left Control Port bit 9 = Stop active on local module’s Right Control Port bit 10 = Stop active due to Stop Command from PLC bit 11 – 15 Reserved |