Register Name / Module Address Assembled Address for PLC Description
Sensor & Control Port Inputs
4:0035
M: 4:1518
E: I.Data [18]
P: Byte 36 (Hi)
   Byte 37 (Lo)
Bitwise Value – Read Only:
   bit 0 = Left Sensor Port – Aux I/O (M8 Pin 2)
   bit 2 = Right Sensor Port – Aux I/O (M8 Pin 2)
   bit 4 = Left Sensor Port – Sensor Signal (M8 Pin4)
   bit 6 = Right Sensor Port – Sensor Signal (M8 Pin 4)
   bit 15 = 2 sec on / 2 sec off heatbeat
   All other bits reserved
Reserved M: 4:1519
E: I.Data [19]
P: Byte 38 (Hi)
   Byte 39 (Lo)
ConveyStop Status
4:0019
M: 4:1520
E: I.Data [20]
P: Byte 40 (Hi)
   Byte 41 (Lo)
Bitwise Value – Read Only:
   bit 0 – 4 Reserved
   bit 5 = Stop active on another module in Stop Group
   bit 6 = Stop active due to lost communication connection
   bit 7 = Stop active due to lost PLC connection
   bit 8 = Stop active on local module’s Left Control Port
   bit 9 = Stop active on local module’s Right Control Port
   bit 10 = Stop active due to Stop Command from PLC
   bit 11 – 15 Reserved