Register Name / Module Address Assembled Address for PLC Description
Set Induct Tracking Forward Direction Word 1
4:0139
M: 4:1612
E: O.Data [12]
P: Byte 24 (Hi)
   Byte 25 (Lo)
Only used when local module is accepting loads from Non-ConveyLinx controlled conveyor:

   Set value for 16-bit integer tracking word #1 for Carton leaving non-ConveyLinx controlled conveyor that is in transit to arrive on the local upstream zone when conveyor is running in default or “forward” direction
Set Induct Tracking Forward Direction Word 2
4:0140
M: 4:1613
E: O.Data [13]
P: Byte 26 (Hi)
   Byte 27 (Lo)
Only used when local module is accepting loads from Non-ConveyLinx controlled conveyor:

   Set value for 16-bit integer tracking word #2 for Carton leaving non-ConveyLinx controlled conveyor that is in transit to arrive on the local upstream zone when conveyor is running in default or “forward” direction
Set Induct Tracking Reverse Direction Word 1
4:0237
M: 4:1614
E: O.Data [14]
P: Byte 28 (Hi)
   Byte 29 (Lo)
Only used when local module is accepting loads from Non-ConveyLinx controlled conveyor:

   Set value for 16-bit integer tracking word #1 for Carton leaving non-ConveyLinx controlled conveyor that is in transit to arrive on the local upstream zone when conveyor is running in opposite of default or “reverse” direction
Set Induct Tracking Reverse Direction Word 2
4:0238
M: 4:1615
E: O.Data [15]
P: Byte 30 (Hi)
   Byte 31 (Lo)
Only used when local module is accepting loads from Non-ConveyLinx controlled conveyor:

   Set value for 16-bit integer tracking word #2 for Carton leaving non-ConveyLinx controlled conveyor that is in transit to arrive on the local upstream zone when conveyor is running in opposite of default or “reverse” direction