The BASE can be operated in a completely manual mode. It is important to keep in mind that the configured Automated mode is optimized for the most efficient operation. However, manual mode may be preferred when a user is experimenting with new geometries or parameters.

From the Home screen, press the MANUAL button to access the Manual Operation Mode screen

Manual Mode options

Page 1 is the Manual Operation Mode screen.

Manual Run Mode, screen one
  • PUMP – Turn the main system pumps on and off.
  • BLOWER – The BLOWER button is used to evacuate vapor from the chamber.
  • HEATER – Heat up fluids in the tank to the temperature set point selected from temperature control slider (see below). In Manual Mode, the HEATER button must be on for the BASE to reach and maintain the desired temperature.
  • DRAIN – Select the DRAIN button to open the respective valve, then the PUMP button to power-drain the detergent from the tank. The valve automatically stops draining once the liquid reaches the lower liquid level sensor. Residual fluids remain in the plumbing below the lower liquid level sensor.
  • SPRAY VALVES – The spray nozzles are activated by pressing the respective SPRAY VALVE buttons located in the center of the screen.
  • FAN – The FAN button should be turned on to allow the fans in the cabinet below the tank to keep the BASE electronics cool enough and avoid damage from overheating. In Auto Run Mode, the software will turn the fans on automatically to perform this function. Fans also help to cool the detergent tank off
  • FILL – Press the FILL button to fill the BASE tank with freshwater only. The fill valve has a sensor that automatically stops filling the tank once the water reaches the top liquid level sensor. The feature is only used during a cleaning cycle or other non-production cycle.
  • DOSE – The DOSE button fills the tank with detergent through the Dosatrons. The dosing valve automatically stops dosing once the detergent level reaches the top of the tank.
  • Temperature SETPOINT – Choose tank temperature setpoint. In Manual Mode, the HEATER button must be on for the BASE to reach and maintain the desired temperature.

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.

Please do not use this for support questions.
Your feedback will remain private. Click here to Request Technical Support.

Post Comment