The BASE is delivered with an industrial power cord. Use only the power cord supplied by PostProcess with the BASE. Based on the model number of the machine, connect the BASE only to the power indicated in the table below.
SR008 | CE | UL/CSA North America |
---|---|---|
MODEL | -02 | -03 |
PHASE | 3 | 3 |
VOLTAGE | 400VAC | 208VAC |
FREQUENCY | 50Hz | 60Hz |
AMPERAGE | 25A | 50A |
Do not place the power cord in a location where it could come into contact with water or other liquid substances. It is recommended to keep the entire power cord suspended above the floor surface.
The BASE utilizes power provided through an industrial power cable/connector located on the upper-right rear of the unit as shown in the images below.
|
|
Power cord location | Power connector |
The MASTER DISCONNECT SWITCH is located on the left access panel of the BASE. Before connecting or disconnecting the BASE to power, ensure the MASTER DISCONNECT SWITCH is in the horizontal “O” or OFF position.
When the power cord is connected to the BASE and plugged into a specified power outlet, turn the POWER switch 90 degrees clockwise to the vertical “I” or ON position. The BASE is now ready to be powered up.
|
|
The MASTER DISCONNECT SWITCH is located on the left access panel, shown above. To turn OFF the MASTER DISCONNECT SWITCH, grasp the switch and rotate counter-clockwise 90˚ to OFF. |