Integrating MotionLinx with TwinCAT / Customizing MotionLinx-Ai PDOs /
Object Dictionary Items Available for Custom PDOs
OD Items Available for TxPDOs
Dictionary Object | Index | Data Type | Data Description |
---|---|---|---|
0×3007 ConveyStop Status |
SubIndex 0 | INT | Integer Value – Indicates the current status of the ConveyStop function 0 = No Stopped Condition Active 2 = Stopped Condition is Active* All other values reserved |
0×3008 CPU Load Percentage |
SubIndex 0 | SINT | Unsigned Value – Indicates the percent loading on the module’s CPU (0 to 100) |
0×4001 Service Read Object |
SubIndex 01 thru 0F |
All SubIndexes of the Service Read Object SDO |
OD Items Available for RxPDOs
Subindex | Index | Data Type | Data Description |
---|---|---|---|
0×2013 ConveyStop Command |
SubIndex 0 | INT | Integer Value 0 = Clear Stopped State 1 = Set Stopped State |
0×4000 Sensor Polarity |
SubIndex 01 | INT | Bitwise Value: bit 00 = Left Sensor Port – Aux Input bit 01 = Reserved bit 02 = Right Sensor Port – Aux Input bit 03 = Reserved bit 04 = Left Sensor Port – Sensor Input bit 05 = Reserved bit 06 = Right Sensor Port – Sensor Input bit 07 thru bit 15 = Reserved |
0×4000 Left Motor Slave |
SubIndex 0B | INT | Integer Value Sets the function of the Left Motor 0 = Left Motor will maintain its own separate control from the Right Motor 1 = Left Motor will “slave” to Right Motor |
0×4000 Right Motor Slave |
SubIndex 0C | INT | Integer Value Sets the function of the Right Motor 0 = Right Motor will maintain its own separate control from the Left Motor 1 = Right Motor will “slave” to Left Motor |
0×2014 Reserved1Byte |
SubIndex 0 | SINT | One Byte Object used to align PDO to a 4-byte boundary |
0×2015 Reserved2Byte |
SubIndex 0 | INT | Two Byte Object used to align PDO to a 4-byte boundary |