DIP Switch Settings / CONFIG DIP Switch /


Motor
Performance
Setting
Applicable
Models
Rated
Current
Starting
Current
Starting
Current
Duration
Application
ECO All Models 2.5A 3A 5 sec. General purpose use, maximum speed of MDR is available
BOOST All Models 3.5A 5A 1.5 sec. Heavier load, maximum speed of MDR is reduced
BOOST 8 EZ-Qube-HTBF-P
EZ-Qube-HTBF-N
3.5A 8A 1.5 sec. Staring heavier load from stop, maximum speed of MDR is reduced
BOOST 7 EZ-Qube-W
EZ-Qube-W-Ai
3.5A 7A 1.5 sec. Staring heavier load from stop, maximum speed of MDR is reduced
PDU MAX EZ-Qube-HTBF-P
EZ-Qube-HTBF-N
8A N/A N/A Only for use with PDU-90 Belt MDRs, allows 6400 motor RPM


DIP Switch settings for EZ-Qube-HTBF-P and EZ-Qube-HTBF-N


Motor Performance Mode CONFIG
SW 5
CONFIG
SW 6
ECO  OFF   OFF 
BOOST  ON   OFF 
BOOST 8  OFF   ON 
PDU MAX  ON   ON