DIP Switch Settings / CONFIG DIP Switch /
Motor Performance Settings
| Motor Performance Setting |
Applicable Models |
Rated Current |
Starting Current |
Starting Current Duration |
Application |
| ECO | All Models | 2.5A | 3A | 5 sec. | General purpose use, maximum speed of MDR is available |
| BOOST | All Models | 3.5A | 5A | 1.5 sec. | Heavier load, maximum speed of MDR is reduced |
| BOOST 8 | EZ-Qube-HTBF-P EZ-Qube-HTBF-N |
3.5A | 8A | 1.5 sec. | Starting heavier load from stop, maximum speed of MDR is reduced |
| BOOST 7 | EZ-Qube-W EZ-Qube-W-Ai |
3.5A | 7A | 1.5 sec. | Starting heavier load from stop, maximum speed of MDR is reduced |
| PDU MAX | EZ-Qube-HTBF-P EZ-Qube-HTBF-N |
8A | N/A | N/A | Only for use with PDU-90 Belt MDRs, allows 6400 motor RPM |
DIP Switch settings for EZ-Qube-HTBF-P and EZ-Qube-HTBF-N

| Motor Performance Mode | CONFIG SW 5 |
CONFIG SW 6 |
|---|---|---|
| ECO | OFF | OFF |
| BOOST | ON | OFF |
| BOOST 8 | OFF | ON |
| PDU MAX | ON | ON |