To find the Acceleration/Deceleration times for speed settings other than 100%, the following simple formula can be used to calculate the value:
Where:
• T = New Ramp Up/Down time
• Speed = New Speed in RPM from CONFIG SW 1 / SPEED SW 1 thru 4
• Max RPM = 5800 for ECO Mode or 4200 for BOOST mode
• TMax = Time value from ACC/DEC chart
Example
For example, let’s say we have selected the CONFIG and SPEED DIP switches for the 4000 RPM setting:
CONFIG SW 1 = ON
SPEED SW 4 thru 1 = OFF/OFF/ON/OFF
And we have selected ACC/DEC DIP switches for the 1.200 second setting:
ACC/DEC SW 4 thru 1 = ON/OFF/ON/OFF
Assuming we are in ECO Mode, our formula looks like: