Module Address Register Name Assembled Address for FW 5.2 Assembled Address for FW 4.25 and earlier
4:0020 ConveyStop Command 4:11800 4:1800
4:0060 Set Left Motor Port Digital Control 4:11801 4:1801
4:0084 Set Right Motor Port Digital Control 4:11802 4:1802
4:0037 Control Port Digital Output Control 4:11803 4:1803
4:0260 Left Motor Run / Reverse 4:11804 4:1804
4:0261 Left Motor Brake Method 4:11805 4:1805
4:0262 Left Motor Speed Control Method 4:11806 4:1806
4:0270 Right Motor Run / Reverse 4:11807 4:1807
4:0271 Right Motor Brake Method 4:11808 4:1808
4:0272 Right Motor Speed Control Method 4:11809 4:1809
4:0040 Left Motor Speed Reference 4:11810 4:1810
4:0064 Right Motor Speed Reference 4:11811 4:1811
4:0043 Left Motor Acceleration Ramp 4:11812 4:1812
4:0044 Left Motor Deceleration Ramp 4:11813 4:1813
4:0067 Right Motor Acceleration Ramp 4:11814 4:1814
4:0068 Right Motor Deceleration Ramp 4:11815 4:1815
4:0022 Clear Motor Error 4:11816 4:1816
4:0196 Set Status to Downstream Module 4:11817 4:1817
4:0116 Set Status to Upstream Module 4:11818 4:1818
4:0034 Sensor Port Input Signal Condition Mask 4:11819 4:1819
4:0201 Set Discharge Tracking Word 1 4:11820 4:1820
4:0202 Set Discharge Tracking Word 2 4:11821 4:1821
N/A Reserved 4:11822 4:1822
4:0008 Left Motor Servo Command Pulses 4:11823 4:1823
4:0009 Left Motor Servo Command Word 4:11824 4:1824
4:0013 Right Motor Servo Command Pulses 4:11825 4:1825
4:0014 Right Motor Servo Command Word 4:11826 4:1826