Tag Name |
Data Type |
Module Register |
Bit |
Description |
O_Clear_Motor_Error |
BOOL |
4:0022 |
0 |
Clear Motor Error Left & Right |
O_Enable_Module |
INT |
- |
AOI Logic |
1 – Move Reset Counter from I.Data(8) to O.Data(8) |
O_Mtr_Dig_Ctrl_Clear_OverCurrent_Left |
BOOL |
4:0060 |
15 |
1 = Clear Over-current error |
O_Mtr_Dig_Ctrl_Clear_OverCurrent_Right |
BOOL |
4:0084 |
15 |
1 = Clear Over-current error |
O_Mtr_Dig_Ctrl_Dig_Outputs_En_Left |
BOOL |
4:0060 |
8 |
0 = Use port as Motor Control, 1 = Use port as Digital Output |
O_Mtr_Dig_Ctrl_Dig_Outputs_En_Right |
BOOL |
4:0084 |
8 |
0 = Use port as Motor Control, 1 = Use port as Digital Output |
O_Mtr_Dig_Ctrl_Pin3_Left |
BOOL |
4:0060 |
0 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dig_Ctrl_Pin3_Right |
BOOL |
4:0084 |
0 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dig_Ctrl_Pin4_Left |
BOOL |
4:0060 |
1 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dig_Ctrl_Pin4_Right |
BOOL |
4:0084 |
1 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dig_Ctrl_Pin5_Left |
BOOL |
4:0060 |
2 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dig_Ctrl_Pin5_Right |
BOOL |
4:0084 |
2 |
Digital Output Control (1 – energized, 0 – clear) |
O_Mtr_Dir_Left |
BOOL |
4:0260 |
8 |
On = Run in Opposite of Config. Dir. |
O_Mtr_Dir_Right |
BOOL |
4:0270 |
8 |
On = Run in Opposite of Config. Dir. |
O_Mtr_Run_Left |
BOOL |
4:0260 |
0 |
On = Run |
O_Mtr_Run_Right |
BOOL |
4:0270 |
0 |
On = Run |
O_Mtr_Speed_Left |
INT |
4:0040 |
- |
Value in 0.1% units of motor %PWM |
O_Mtr_Speed_Right |
INT |
4:0064 |
- |
Value in 0.1% units of motor %PWM |
Post your comment on this topic.