ConveyLinx-ECO Module status is indicated by several LED’s. All LED’s with the exception of the Ethernet Link and Activity LEDs are multi-colored and context sensitive. The following sections indicate the various meanings of all LED indicators.

If you need help finding where LED Items are located on the ConveyLinx-ECO Module

Communications

Indicator Item LED State Description
Link Left & Right & OFF No connection established
Solid Green Connection is established
Blinking Green When data transmission activity is occurring

Motors

Indicator Item LED State Description
Motor Left & Right & OFF Motor is not running and no faults detected
Solid Green Motor is running
Solid Red If Motor is running – indicates current limit
If Motor is stopped – indicates motor is not connected properly or is overheated
Power supply is under 18V or above 30V
Blinking Red Motor is overloaded and the module is limiting current to reduce temperature
Flashing Red Motor short circuit detected between at least two of the phase windings or Motor Power supply is less than 10V
Solid Amber Module is booting up
Slow Blinking Red Profinet enabled discover function initiated from PLC

Module Status

Indicator Item LED State Description
Module Status Blinking Red Module is starting task processes
Blinking Green Module is ready
Flashing Green & Blinking Red Failsafe Mode
Flashing Red Auto Configure Mode is active
Blinking Amber Connection to peer lost or performing firmware upgrade check
Solid Amber Firmware upgrade in progress
Slow Blinking Red Replacement procedure time-out in progress

Sensor Indicators

Indicator Item LED State Description
Sensors Left & Right & Solid Green Sensor Input is energized
Solid Amber Module is booting up
Flashing Green When in ZPA Mode and when Sensor is blocked – indicates external device (PLC/PC controller or EasyRoll) has accumulated the zone and inhibiting release
Blinking Red Arrival Jam or missing sensor
Blinking Green/Amber Sensor Jam
Flashing Amber Power supply is less than 10V
Slow Blinking Red Profinet enabled discover function initiated from PLC

Aux Input Indicators

Indicator Item LED State Description
Aux Left & Right & Solid Amber Module is booting up
Solid Red Local Aux Input energized
Flashing Amber Power Supply is less than 10V
Slow Blinking Red Profinet enabled discover function initiated from PLC

Special Cases

Indicator Item LED State Description
All Sensors & Motors Flashing Red Module in stopped state
Left Sensor & Left Motor Flashing Green ZPA zone on left side of module is in Maintenance Mode*
Right Sensor & Right Motor Flashing Green ZPA zone on right side of module is in Maintenance Mode*