For ATevos rated 30-50 Adc, the Filtering Assembly (A7) consists of a capacitor bank (C1x) and bleed resistors (R9x) mounted on a printed circuit board. ATevos rated 75-100 Adc, feature discrete blue electrolytic filter capacitor ‘cans’ (C1x).

Preparation:

  • Shut down and lock out all power to ATevo.
  • Wait several minutes to allow internal potentials in capacitors to bleed off.
  • Remove safety shield.

Removal (30-50 Adc):

  • Locate Filter Board (A7) on top of heatsink, above Power Board (A2) and rectifier, along left side of ATevo.
  • Remove two (2) nuts from studs connecting Power Board to Filter Board.
  • Remove one (1) screw at top center of Filter Board.
  • Remove existing Filter Board (A7) assembly.

Installation (30-50 Adc):

  • Place new Filter Board (A7) onto studs of Power Board and replace two (2) nuts and (1) screw.
  • Replace safety shield, close door, and restart ATevo.

For 75 Adc and 100 Adc ATevos:

  • Locate the C1 discrete capacitor can(s) near the top left of the enclosure.

Removal of Existing Capacitor (C1x) Assembly (75 Adc and 100 Adc):

  • Remove the screws attaching the capacitor to connection wires and/or bus bar.
  • Loosen the screw on the capacitor bracket at the bottom of the capacitor mounting.
  • Make note of the polarization of the capacitor (+ and – terminals).
  • Remove capacitor(s) from bracket(s).

Installation of New C1 Capacitor Assembly (75 Adc and 100 Adc):

  • Place new capacitor(s) into brackets maintaining the same polarity as the one(s) removed.
  • Tighten the screw(s) on the capacitor bracket(s).
  • Reconnect the connection wires and/or busbars in the same location using the capacitor terminal screws
  • Replace safety shield, close door, and restart ATevo.
Last modified: 5 May 2021